3.0 Operation 3.1 Ribbon Cartridge Loading (see the video at www.craden.com/ribbonchg.wmv ) Generic ribbons may cause printer malfunctions includi
Commands unique to I mode: ESC 0 sets line spacing to 1/8 inch. ESC 1 sets line spacing to 7/72 inch. ESC 2 sets line spacing stored by a prior ESC
ESC X mn sets left and right margins at columns m and n. Printing begins at column m and must stop at column n. The document may be no wider than (n+
ESC~C clears all data out of the buffer and switches the interface to Mode C. 3.10.4 Low Density Graphics Commands These commands emulate low-densi
3.10.7 Configuration Commands HT changes the machine configuration and must be followed by 2 characters of the form 01PVHFCS and 01LEIBDQ where: P =
DC1 or DLE request keypad data. Upon receipt of either, all keypad input that has been pressed since the previous DC1 or DLE will be tr
3.11.2 Installing Craden Drivers on WINDOWS NT, 2000, XP, VISTA, OR 7 (32-bit): A firmware upgrade may be required to run the Vista/7 driver. C
12cpi, and lowest quality, fastest printing draft 10 and 12cpi. Draft should not be used on passbooks. These fonts can be selected like any other fon
3.12.3 Interface Signals & Cables The interface provides for RS-232 communication. All signals are available on a 9 pin male connector equivalen
3.13.3 No Document Motion If a document will not advance upon insertion: 1. Press EJECT if a previous document had been manually removed w
3.2 Keypad Operation EJECT: ejects an inserted document if the print buffer is empty. Should a document remain partially in the printer, press
3.4 Document Insertion Insertion procedures may be customized to satisfy varied applications and user preferences. (See the Printer Parameters in
3.5.1 Printer Parameters Press 9 2 FUNCT to display the following parameters or press 9 0 0 FUNCT to print them on a previously inserted document
3.5.2 Communication Parameters Press 9 3 FUNCT to display the following Communication Parameters or press 9 0 0 FUNCT to print them on a previously
3.5.4 Service Parameters Press 9 4 FUNCT to display the following Service Parameters. These parameters are factory set specifically for each printer
3.6.2 Enhanced Diagnostics Diagnostics execute after pressing 9 0 FUNCT. If no faults exist, PROM REVISION XX, ROM TEST OK and RAM TEST OK
3.10 Programming CAUTION: DURING PROGRAM DEVELOPMENT ALL PRINTING SHOULD BE DONE ON SINGLE SHEET PAPER UNTIL PRINT IS CORRECTLY FORMATTED. PRINTING
ESC H 1B 48 End correspondence quality print ESC I n 1B 49 n Begin CQ (n=2) or normal (n=0) print ESC J n 1B 4A n Feed document up n/216 inches E